HomeMy WebLinkAboutPC Reso 86-041 PA 86-060.1 .2 Dublin Security Storage RESOLUTION NO. 86 - 041
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF DUBLIN
APPROVING PA 86-060.1 AND .2 DUBLIN SECURITY STORAGE
CONDITIONAL USE PERMIT/SITE DEVELOPMENT REVIEW
6031 SCARLETT COURT
WHEREAS, Glenn Kierstead, representing Dublin Security Storage,
submitted Conditional Use Permit and Site Development Review requests for a
three-phased development of a partially developed 6.6±acre site with new
development proposed to consist of three two-story mini-storage structures
(70,000+ sq. ft. cumulative area) and the development of exterior vehicle
storage and with additional work to include conversion of two existing
buildings for mini-storage use (12,600± sq. ft. cumulative area) and general
site work; and
WHEREAS, the adopted City of Dublin Zoning Ordinance, which in part
provides for the establishment of uses in M-1, Light Industrial Districts,
lists storage as a permitted use, and lists outdoor storage as a conditionally
permited use; and
WHEREAS, the Planning Commission did hold a public hearing on said
applications on August 4, 1986; and
WHEREAS, proper notice of said public hearing was given in all
respects as required by law; and
WHEREAS, a Negative Declaration of Environmental Significance,
prepared in accordance with the California Environmental Quality Act (CEQA) by
the Dublin Planning Department, was considered and adopted by the Planning
Commission (Resolution No. 86-040) with a determination that the project would
not have a significant environmental impact; and
WHEREAS, the Staff Report was submitted recommending that the
Conditional Use Permit and Site Development review requests be conditionally
approved; and
WHEREAS, the Planning Commission did hear and consider all said
reports, recommendations and testimony herein above set forth;
NOW, THEREFORE, BE IT RESOLVED THAT THE Dublin Planning Commission
finds:
1. The proposed expansion of the Dublin Security Storage Mini-Storage
facility serves the public need by providing for, in part, the existing
demand for small rental storage spaces.
2. The proposed use will be properly related to other land uses, and
transportation and service facilities in the vicinity.
3. The use will not materially adversely affect the health or safety of
persons residing or working in the vicinity or be materially detrimental
to the public welfare or injurious to property or improvements in the
neighborhood, as all applicable regulations will be met.
4. The use will not be contrary to the specific intent clauses for
performance standards established for the District in which it is to be
located.
5. All provisions of Section 8-95.0 through 8-95.8 Site Development Review,
of the Zoning Ordinance are complied with.
-1-
r'1
6. Consistent with Section 8-95.0, this project will promote orderly,
attractive, and harmonious development, recognize environmental
limitations on development; stabilize land values and investments; and
promote the general welfare by preventing establishment of uses or
erection of structures having qualities which would not meet the specific
intent clauses or performance standards set forth in the Zoning Ordinance
and which are not consistent with their environmental setting.
7. The approval of the project will not conflict with the best interests of
the public as regards public health, safety and general welfare.
8. General site considerations, including site layout, orientation, and the
location of buildings, vehicular access, circulation and parking,
setbacks, height, public safety and similar elements have been designed
to provide a desirable environment for the development.
9. General architectural considerations including the character, scale and
quality of the design, the architectural relationship with the site and
other buildings, building materials and colors, screening of exterior
appurtenances, exterior lighting and signing and similar elements have
been incorporated into the project in order to insure compatibility of
this development with its design concept and the character of adjacent
buildings and uses.
10. General project landscaping and consideration including the locations,
type, size, color, texture and coverage of plant materials, provisions
for irrigation, maintenance and protection of landscaped areas and
similar elements have been considered to insure visual relief to
complement buildings and structures and to provide an attractive
environment to the public.
BE IT FURTHER RESOLVED that the Dublin Planning Commission does
hereby approve said application as shown on Exhibit "A" on file with the Dublin
Planning Department and subject to the following conditions:
CONDITIONS OF APPROVAL, PA 85-060.1 AND .2
Unless stated otherwise, all Conditions shall be complied with prior to
issuance of building or grading permits and shall be subject to Planning
Department review and approval.
GENERAL REQUIREMENTS
1. Development shall generally conform with the plans prepared by Richard A.
Bohn, Jr., A.I.A. consisting of four sheets dated received by the City
Planning Department, July 23, 1986, modified to generally reflect the
changes called for by the three Staff Studies prepared for this project
and the changes called for by these Conditions of Approval. Use of the
proposed mini-storage facility (and the interim use of the two existing
structures) shall be as generally described in the Written Statement
dated received June 20, 1986. Collectively, these materials shall serve
as Exhibit "A" for this project and shall be maintained on file with the
Planning Department. This approval shall be valid until August 14, 1987.
If construction has not commenced by that time, this approval shall be
null and void. This approval period may be extended one additional year
(Applicant must submit a written request for the extension prior to the
expiration date of the permit) by the Planning Director upon his
determination that the Conditions of Approval remain adequate to assure
that the above stated findings will be met. Development shall be subject
to the conditions listed below.
2. Comply with the City of Dublin Site Development Review Standard
Conditions and the City of Dublin Police Services Standard Commercial
Building Security Recommendations. (See Attachments A and B.)
-2-
r1 r1
ARCHAEOLOGY
3. If, during construction, archaeological remains are encountered,
construction in the vicinity shall be halted, an archaeologist consulted,
and the City Planning Department notified. If, in the opinion of the
archaeologist, the remains are significant, measures, as may be required
by the Planning Director, shall be taken to protect them.
ARCHITECTURAL
4. The final design of building elevations and the choice of exterior colors
and materials proposed for use shall be subject to final review and
approval by the Planning Director. All ducts, meters, air conditioning
equipment and other mechanical equipment on the new structures shall be
effectively screened from view with materials architecturally compatible
with the main structure.
BASIS FOR RELEASE OF OCCUPANCY
5. Prior to release of occupancy, all improvements shall be installed as per
the approved landscaping and irrigation plans and the drainage and
grading plans. Additionally, grading of the subject property must
conform with the recommendations of the soils engineer to the
satisfaction of the City Engineer.
DRAINAGE
6. Grading, drainage and paving improvements shall be subject to review and
approval by the City Engineer. Calculations (hydraulic) shall be
prepared by the developer for review by the City Engineer to determine
the sizing of drainage lines. The Developer shall install storm drainage
improvements as directed by the City Engineer.
7. The proposed wall along the westerly property line shall not block
drainage from the adjacent property. An inlet shall be provided at the
low point.
8. The area outside the building shall drain outward at a 2% minimum slope
for unpaved areas and a 1% minimum in paved areas (5% maximum slope for
paved areas).
9 Roof drains shall empty onto paved areas, concrete swales, or other
approved dissipating devices and shall not direct roof water onto
adjacent properties.
10. Where storm water flows against a curb, a curb with gutter shall be used.
The flow line of all asphalt paved areas carrying waters shall be slurry
sealed at least three feet on either side of the center of the swale.
11. The pad elevation for the new buildings shall be certified by a
Registered Civil Engineer for checking against the 100-year flood
elevation (requiring a minimum finished floor elevation for all new
buildings of 330 on the National Geodetic Vertical Datum of 1929 or as
determined by the City Engineer).
12. The 12' x 14' rectangular concrete channel shall be extended northwards
to a point approximately 20 feet from the northerly property line of
APN 941-550-34, or as otherwise directed by Zone 7 of the Alameda County
Flood Control and Water Control District.
13. In accordance with Alameda County Ordinances No. 81-18 and No. 81-30, as
adopted by the City of Dublin, substantial improvement of the existing
buildings requires that they be protected by either of the following:
A) Having the lowest floor, including basement, elevated to or above
the level of the base flood; or
-3-
B) Providing engineered dikes to at least one (1) foot above the level
of the base flood around the development and, together with
attendant utility and sanitary facilities, be floodproofed so that
below the elevation of the base flood level the structure is
watertight with walls substantially impermeable to the passage of
water and with structural components having the capability of
resisting hydrostatic and hydrodynamic loads and the effects of
buoyancy. A Civil Engineer or Architect registered by the State of
California shall state that the standards of this subsection are
satisfied.
Note: Substantial improvement means any repair, reconstruction, or
improvement of a structure, the cost of which equals 50 percent of
the market value of the structure.
DEBRIS/DUST/CONSTRUCTION ACTIVITY
14. Measures shall be taken to contain all trash, construction debris, and
materials on-site until disposal off-site can be arranged. The developer
shall keep adjoining public streets free and clean of project dirt, mud,
and materials during the construction priod. Developer shall be
responsible for corrective measures at no expense to the City of Dublin.
Areas undergoing grading, and all other construction activities, shall be
watered, or other dust-palliative measures used, to prevent dust, as
conditions warrant.
15. The number, design, placement and means of access of trash enclosures
shall be subject to review and approval by the Planning Director as part
of the Landscape and Irrigation Plan. The design of trash enclosures
shall reflect dimensional criteria of the Livermore-Dublin Disposal
Service.
EASEMENTS
16. The developer shall grant the necessary maintenance easement right-of-way
grant through APN 941-550-33 to the Alameda County Flood Control and
Water Conservation District for the existing 12' x 4' rectangular
concrete channel.
17. The developer shall acquire easements, and/or obtain rights-of-entry from
the adjacent property owners for any improvements, including grading,
required outside of the proposed development. Copies of the easements
and/or rights of entry shall be in written form and be furnished to the
City Engineer.
FIRE
18. Prior to issuance of building permits, the developer shall supply written
confirmation that the requirements of the Dublin San Ramon Services
District Fire Department have been, or will be, met. The developer is
advised that the Fire Department's initial comments on the project
indicate that an additional fire hydrant will be required to serve the
project and that, if windowless second story construction is utilized,
automatic smoke removal vents will be required (as called for in the
District's letter of August 4, 1986 - see Attachment C).
GRADING
19. Grading shall be completed in compliance with the construction grading
plans and the soil engineering recommendations as established by a Soil
and Foundation Study prepared for this project (subject to review and
approval by the City Engineer). The report shall discuss the compaction
of soil under the proposed building and shall comment on the necessary
setback from the existing slope. If grading on the adjacent property to
the West is necessary to backfill the wall and/or to make sure that the
area will drain into the pipe or downstream ditch, written permission
shall be obtained to do the offsite work prior to the issuance of a
grading permit.
-4-
LANDSCAPING AND IRRIGATION PLANS
20. A detailed Landscape and Irrigation Plan, along with a cost estimate of
the work and materials proposed, shall be submitted for review and
approval by the Planning Director. Landscape and Irrigation Plans shall
be signed by a licensed landscape architect.
21. The Developer shall sign and submit a copy of the City of Dublin
Landscape Maintenance Agreement. (See Attachment D.)
LIGHTING
22. Exterior lighting shall be of a design and placement so as not to cause
glare onto adjoining properties. Lighting used after daylight hours
shall be minimized to provide for security needs only. Wall lighting
along the new buildings shall be supplied to provide "wash" security
lighting, and shall be subject to review and approval by the Dublin
Police Services Department and the City Engineer.
PARKING AND DRIVEWAYS
23. The driveway widths surrounding all new buildings shall be a minimum
width of twenty-five feet (measured between buildings and between
buildings and adjoining parking and/or landscape areas). An exception to
this standard shall be allowed along the west side of Building "A" and
the northeast side of Building "E" where the driveway width may be
reduced to 22' to allow the creation of a 6' width perimeter landscape
planter running the length of the respective buildings.
24. Minimum slope on A. C. parking lot shall be 1%, maximum slope to be 5%.
25. The layout and design of the exterior R. V. unit, passenger car and/or
truck storage areas across the entire site (both APN 941-550-033 and 034)
shall be subject to review and approval by the Planning Director prior to
occupancy of the new buildings. A continuous raised concrete curb shall
be provided for parking along the north and west property lines which
shall maintain a minimum setback of three feet from the property line to
accommodate vehicular overhangs.
26. The parking and driveway surfacing shall be asphalt concrete paving. The
City Engineer shall review the project's Soils Engineer's structural
pavement design.
27. PHASE I - IMPROVEMENTS AND DESIGN MODIFICATIONS
A. Install continuous 6-inch raised curbing (300'+) along the existing flood
control channel along the east side of APN 941-550-033, and install
landscaping and irrigation in that area comparable to that planted within
the adjoining area to the south.
B. Install a cul-de-sac turnaround with a 70 foot diameter, including
perimeter curb and gutter and accompanying landscaping and irrigation,
and a formal driveway access for Burke Forms lease space. An alternative
means for vehicular turnaround movements may be utilized if deemed
acceptable by the City Engineer. Temporary asphalt curbing may be
utilized for any interim turnaround area. The final design of the
required turnaround area shall utilize raised concrete curbing and
gutter.
C. Install six-foot cyclone fence with redwood inserts along north and west
boundaries of the two subject parcels (see Condition #36).
D. Adjust entry gate access for existing entrance to provide for emergency
police and fire access (see Condition #37).
E. Provide a secondary gated emergency access to Buildings A and B (to be
provided in conjunction with imposition of a restriction on storage of
any materials within a 20' access zone extending from the new cul-de-sac
across Burke Forms lease holding to the new gated access. This access
shall also be designated for emergency access (police and fire).
-5-
n n
F. Install a continuous raised 6" curb observing a three-foot minimum
setback from the property line and including adequate "pop-outs" to
accommodate a tree planting program reflecting an average planting ratio
of 1 tree @ 17'; curbing and landscaping are to be installed along the
west boundary of APN 941-550-034 and shall continue along the west
portion of the north boundary of that parcel for a minimum distance of
175± feet.
G. Adjust the size and/or location of Building B by bringing its southern
edge 13+ feet further south to a point that will accommodate a straight
25-foot minimum width driveway between the three planned two-story
buildings at full development.
H. Modify the striping plan by adjusting the number, location and
configuration of drive aisles and exterior long-term parking spaces to
promote improved internal circulation. (Adjust plan to be generally
reflective of Staff Study - Phase I, dated July, 1986.)
I. Identify a minimum of five standard sized parking spaces adjoining
Buildings A and B for use by mini-storage space renters. (Location shall
be generally reflective of Staff Study - Phase I, dated July, 1986).
28. PHASE II - IMPROVEMENTS AND DESIGN MODIFICATIONS
A. Install continuous six-inch raised curbing along the remainder of the
north property line (observing a minimum setback of three feet) with
provision of adequate pop-outs to provide for a tree planting program
with an average planting ratio of 1 tree @ 17 feet linear distance.
B. Remove interior fence that defined lease area for Burke Forms with the
Phase I layout.
C. Install a modified secondary access gate off of the cul-de-sac bulb. The
design and location of the gates shall be subject to review and approval
by the Planning Department and the appropriate emergency service
agencies. "Knox-box" keyed access for emergency entrance shall be
supplied, or an equivalent method of access determined acceptable to the
Police and Fire agencies.
D. Modify the striping plan by adjusting the number, location and
configuration of drive aisles and exterior long-term parking spaces to
promote improved internal circulation. (Adjust plan to be generally
reflective of the Staff Study - Phase II, dated July, 1986).
E. Provide a minimum of two'standard sized parking spaces adjoining building
C and two parking spaces adjoining Building E for use by mini-storage
space renters. (Location shall be generally reflective of the Staff
Study - Phase II, dated July, 1986.)
F. Provide a minimum of three standard sized parking spaces adjoining the
"office/warehouse" area of Building E for use by employees or visitors.
(Location shall be generally reflective of the Staff Study - Phase II,
dated July, 1986.)
29. PHASE II - IMPROVEMENTS AND DESIGN MODIFICATIONS
A. Modify the striping plan by adjusting number, location and configuration
of drive aisles and exterior long-term parking spaces to promote improved
internal circulation. (Adjust to be generally reflective of the Staff
Study - Phase III, dated July, 1986.)
B. Provide a minimum of four standard sized parking spaces adjoining
Building D for use by mini-warehouse space renters. (Location shall be
generally reflective of Staff Study - Phase III, dated July, 1986.)
SIGNAGE
30. Any new project signs shall be subject to review and approval by the
Planning Director prior to installation.
-6-
STORAGE AND EXTERIOR ACTIVITIES
31. Additional outside storage, beyond vehicular storage referenced in
Condition #22, is expressly prohibited. All demonstrations, displays,
services, and other activities shall be conducted entirely within the
structures on the site. No loudspeakers or amplified music shall be
permitted outside the enclosed structure.
TITLE
32. A current title report and copies of the recorded deeds of all parties
having any recorded title interest in the property to be developed and,
if necessary, copies of deeds for adjoining properties and easements
thereto, shall be submitted at the time of submission of the drainage
and/or grading plans to the City Engineer.
MISCELLANEOUS
33. Pedestrian walkway areas serving the new buildings shall be of a minimum
width of five feet.
34. The materials used for new pedestrian walkways shall be of a uniform
design and shall be subject to review and approval of the Planning
Director. Those portions of walkways adjoining parking areas shall be
raised 6" above the level of the parking/drive aisle surface.
35. Parking areas on the end of the proposed Building D shall be physically
separated from the building by way of a raised concrete walkway, which
shall doubly serve to provide access to the east side of the structure.
36. Screen fencing, six-foot high cyclone fencing with redwood slat inserts
or equivalent, shall be established with the first phase of the
development along the north and west property lines of the subject
property. For security purposes, the height of this fence may be
increased to include "three-strand" barbed-wire security treatment above
the six-foot high cyclone fence. For the west property line, the
existing adjoining fencing on APN 941-550-19-3, -4 and -5 may be used to
satisfy this requirement to the extent that it covers the subject
property's west boundary and for as long as it remains in place and in
good condition.
37. The design and location of fences utilized in the project shall be
subject to review and approval by the Dublin City Police Services. A
Knox override switch for the gate entrance into the project shall be
provided to allow emergency police and fire access. An alternate means
to provide emergency access to the property may be utilized if approved
by the DSRSD Fire Department and the Dublin City Police Services.
38. Except as specifically altered by the above conditions of approval,
development shall comply with the conditions established for S-689. (See
Attachment E.)
PASSED, APPROVED AND ADOPTED this 4th day of August, 1986.
AYES: Commissioners Barnes, Burnham, Mack, Petty and Raley
NOES: None
ABSENT: None
.Planning ommission Chairperson
ATTEST:
Planning Director
-7-